Availability: | |
---|---|
Quantity: | |
Versatile High-Power Output
Intelligent Power Distribution
Power Cabinet | |
Project | Technical parameters |
Power cabinet rated power | 360~540kW |
Single module power | 30kW |
Number of DC output buses | 8 (quantity optional) |
Switching Type | Full dynamic module switching |
Output voltage range | 150 ~ 1000VDC |
Constant power output voltage | 300 ~ 1000VDC |
Voltage stabilization accuracy | ≤±0.5% |
Steady current accuracy | ≤±1% |
AC input voltage | AC380V ± 15% (3P + N + PE) |
AC input frequency | 50 Hz ± 1 Hz |
AC Rated Input Current | 2 * 437A |
Power factor | ≥ 0.98 (50% < PO/PN ≤ 100%) |
Current Harmonics (THDi) | ≤5% |
Peak efficiency | ≥95% |
Noise | ≤ 70 dB |
Level of protection | IP54 (outdoor installation) |
Installation method | Floor-standing |
Overall dimensions | 1500mm × 1000mm × 2000mm (width × depth × height) |
Operating ambient temperature | -20℃~50℃ |
Relative humidity | 5%~95% |
Altitude above sea level | ≤ 2000 m |
Installation vertical inclination | ≤5% |
Installation location | Indoor or outdoor |
Note: There shall be no strong vibration and shock in the use place, no explosive dangerous media, and the surrounding media shall not contain harmful gases and conductive media that corrode metal and destroy insulation. |
Liquid-cooled overcharging terminal | |
Project | Technical parameters |
Rated output power | 500kW |
Number of charging interfaces | 1 |
Charging interface type | CCS2 |
Output voltage range | 150 ~ 1000VDC |
Maximum output current | 500A (Ongoing) |
Auxiliary power supply | Standard 12V (24V needs to be customized) |
Heat dissipation method | Intelligent liquid cooling |
Noise | ≤ 60 dB |
Human-computer interaction | Screen + LED |
Charging start mode | Scan QR code to charge |
Mode of communication | Ethernet |
Length of gun line | Standard with 5 meters (more lengths can be customized) |
Level of protection | IP54 (outdoor installation) |
Installation method | Floor-standing |
Overall dimensions | 550mm × 352mm × 1550mm (width × depth × height) |
Operating ambient temperature | -20℃~50℃ |
Relative humidity | 5%~95% |
Altitude above sea level | ≤ 2000 m |
Installation vertical inclination | ≤5% |
Installation location | Indoor or outdoor |
Note: There shall be no strong vibration and shock in the use place, no explosive dangerous media, and the surrounding media shall not contain harmful gases and conductive media that corrode metal and destroy insulation. |
Intelligent fast charging terminal | |
Project | Technical parameters |
Rated output power | 200kW |
Number of charging interfaces | 1 |
Charging interface type | CCS2 |
Output voltage range | 150 ~ 1000VDC |
Maximum output current | 200A (continuous) |
Auxiliary power supply | Standard 12V (24V needs to be customized) |
Heat dissipation method | Air cooling |
Noise | ≤ 60 dB |
Human-computer interaction | Indicator light |
Charging start mode | Scan QR code to charge |
Mode of communication | Ethernet |
Length of gun line | 4.5 meters as standard (more lengths can be customized) |
Level of protection | IP54 (outdoor installation) |
Installation method | Floor-standing |
Overall dimensions | 350mm × 200mm × 1550mm (width × depth × height) |
Operating ambient temperature | -20℃~50℃ |
Relative humidity | 5%~95% |
Altitude above sea level | ≤ 2000 m |
Installation vertical inclination | ≤5% |
Installation location | Indoor or outdoor |
Note: There shall be no strong vibration and shock in the use place, no explosive dangerous media, and the surrounding media shall not contain harmful gases and conductive media that corrode metal and destroy insulation. |